OCEANMAX 6RT Riser Tensioner
- Compliant to International Standards.
- High fatigue resistance.
- High dimensional stability.
- Enhanced sheave imprinting resistance if dual strength.
Nominal Diameter | Mass | Minimum Breaking | |||||||
---|---|---|---|---|---|---|---|---|---|
Metric | Imperial | Metric | Imperial | Metric | Imperial | ||||
Air | Water | Air | Water | 1770 dual | IPS/1770 | 1770 dual | IPS/1770 | ||
mm | Inches | kg/m | kg/m | lb/ft | lg/ft | kN | kN | Tonnes | Tonnes |
44 |
|
8.71 8.89 10.4 |
7.41 7.56 8.81 |
5.87 5.99 6.98 |
4.99 5.09 5.93 |
1450 1480 1730 |
1530 1560 1820 |
148 151 176 |
156 159 186 |
52 54 |
2 2 1/8 |
11.6 12.2 13.1 |
9.87 10.3 11.2 |
7.82 8.19 8.83 |
6.65 6.96 7.51 |
1940 2030 2190 |
2040 2140 2300 |
198 207 223 |
208 218 234 |
56 |
|
14.1 15.1 16.4 |
12.0 12.9 13.9 |
9.50 10.2 11.0 |
8.08 8.66 9.37 |
2350 2520 2730 |
2480 2660 2870 |
240 257 278 |
253 271 293 |
64 |
2 1/2 |
18.4 20.0 22.1 |
15.7 17.0 18.7 |
12.4 13.5 14.8 |
10.5 11.4 12.6 |
3070 3330 3680 |
3240 3510 3870 |
313 339 375 |
330 358 394 |
73 |
2 7/8 |
24.0 26.0 |
20.4 22.1 |
16.2 17.5 |
13.7 14.9 |
4000 4330 |
4210 4560 |
408 441 |
429 465 |
These figures are for guidance only. Other features such as MBF, dimensions, lay type and plastic fill can be designed on request.